Vulcan Hart V24 Gas Range
The Vulcan Hart V24 is a gas restaurant range in the V Series medium-duty range family. Its manual covers gas installation, pilot lighting, oven operation and cleaning; the parts catalog identifies V24 oven and drip-pan components.
- Gas Type
- Natural gas or propane
Vulcan Hart V24
104 compatible parts available
Genuine OEM Parts
Sourced from the manufacturer
Canadian Owned
Based in British Columbia
Canada-Wide Shipping
Every province and territory
24hr Quote Response
Answered by a real technician
Manuals & Documents
About the Vulcan Hart V24
Overview
The Vulcan Hart V24 is included in Vulcan-Hart’s V Series medium-duty gas restaurant range documentation. Its installation and operation manual covers gas supply preparation, pilot lighting, oven operation and cleaning. The parts catalog identifies V24-specific components, including an oven door assembly, a standard-oven rack and a drip-pan assembly. The catalog also contains griddle-body parts information; it does not establish that every V24 has the same cooking-surface configuration.
The manual describes the range as equipment requiring appropriate installation, use and maintenance for satisfactory performance. It states that qualified personnel should install gas equipment and perform initial field start-up and adjustments.
Key Features
- Gas operation: The manual addresses natural-gas and propane supplies and gives regulator settings for both.
- Open-top burners and pilots: The lighting instructions cover open-top burner pilots and explain nightly and complete shutdown.
- Oven operation: The manual includes standard-oven pilot-lighting instructions, rack guidance and cooking recommendations.
- V24 parts identification: The parts catalog lists a V24 oven door assembly, a 24-inch standard-oven rack and a V24 drip-pan assembly.
Specifications
- Model: V24.
- Equipment type: Gas restaurant range; listed in the V Series medium-duty range parts catalog.
- Gas types addressed in the manual: Natural gas and propane. Confirm the required gas type on the range rating plate before installation.
- Gas connection: 3/4-inch (19 mm) 14 FPT ANSI Schedule #40 standard pipe.
- Regulator settings stated in the manual: Natural gas, 4 inches water column (0.99 kPa); propane, 10.0 inches water column (2.5 kPa).
- Minimum clearance from combustible construction: 12 inches (304 mm) at the sides and 10 inches (253 mm) at the rear.
- Minimum clearance from non-combustible construction: 0 inches at the sides and 6 inches (152 mm) at the rear.
- Minimum front clearance: 40 inches (1016 mm).
- Standard-oven rack positions: Two; the manual says the standard oven is supplied with one rack.
- V24 parts listed in the catalog: Standard-oven rack 00-417248-00001; oven door assembly 00-957910-000G3; drip-pan assembly 00-499611-000G3, which includes pan 00-499603-00002 and 24-inch drip-pan handle 00-424919-00001.
Installation & Requirements
Before installation
After unpacking, inspect the range for shipping damage. The manual instructs operators to retain the packaging and contact the carrier within 15 days of delivery if damage is found. Remove shipping wire and wood blocking, then check the rating plate inside the lower kick panel. The gas supply must match the type specified on that plate. The manual also says to check electrical service for convection-oven series ranges; it does not provide an electrical specification for the V24 in the supplied material.
Location and air supply
Keep the equipment area clear of combustible substances. Allow the listed clearances from surrounding construction and at the front of the range. The installation location must leave room for servicing and operation. Do not obstruct the flow of combustion or ventilation air, and provide adequate room air for gas combustion and adequate clearance at the combustion-chamber air openings.
Gas connection and regulator
Before lighting, check gas-supply joints for leaks with a soap-and-water solution; the manual expressly says not to use an open flame. After checking the piping, purge gas-receiving lines fully. It also cautions against overtightening the thermocouple: tighten it one-quarter turn past finger-tight.
Operation
Open-top burner pilots
Turn on the main gas supply and wait 30 seconds before lighting the open-top pilot with a taper. If it does not light, turn off the main gas supply, wait 5 minutes and repeat the procedure. Turn one open-top burner valve on to clear air from the line, then turn it off when gas begins to flow. For nightly shutdown, turn the burner valve off; the pilot remains lit. For complete shutdown, turn the burner valve off and turn off the main gas supply. The manual gives similar pilot-lighting and shutdown instructions for hot-top and griddle-top burners where those sections apply.
Standard oven
Light the open-top or griddle pilots before lighting the oven pilot. The manual’s standard-oven procedure begins with the thermostat in the OFF position and a 5-minute wait. Remove the lower panel, depress the red safety-valve button and light the pilot through the observation area. Hold the button down for at least 30 seconds; when released, the pilot should remain lit. Replace the lower panel and set the thermostat to the desired temperature. If the pilot goes out, repeat the procedure. For nightly shutdown, turn the oven thermostat off. For complete shutdown, turn the thermostat off and turn off the main gas supply.
The standard oven has two rack positions and is supplied with one rack. For cakes and pastries, the manual recommends using one rack position. Rack placement otherwise depends on the operator’s cooking needs. For a large roast, it says the rack may be removed and the roasting pan placed directly on the oven bottom. To clear odors that may remain after initial operation, the manual recommends running the unloaded oven at 500°F (260°C) for 30 to 45 minutes.
Cleaning & Maintenance
The manual warns that the range and its parts are hot during operation, cleaning and servicing. Let hot components cool before handling them. Empty the broiler grease pan or trough daily or as needed; the manual recommends emptying it when it is three-quarters full and cautions operators to remove it slowly because liquid may move inside. Wash the drip shield, grids and grease pan or trough with a mild grease-dissolving solution. Regularly scrub the broiler chamber and body front to reduce smoking.
Clean cast-iron open-top grates with mild soap and water, rinse thoroughly and dry with a clean, absorbent towel. With the grates removed, apply a light coating of liquid vegetable oil or spray-type cooking oil. Replace the grates, turn the open-top sections to LOW and let them burn for at least 15 minutes before placing pots or pans on them. The manual says to season the grates after each cleaning to help prevent rust. Weekly, boil burners in a washing-soda solution, then rinse and dry them thoroughly. When reinstalling burner heads, ensure they are properly connected. Do not light a pilot or turn on a burner valve with a burner head removed.
For a griddle-equipped configuration, the manual says to clean the surface after use with a wire brush or flexible spatula. Clean the backsplash, sides and front daily, and empty and wash the grease pan. While the surface is warm, clean with a griddle stone, wire brush or steel wool, working with the grain of the metal. If detergent is used, remove it thoroughly and apply a thin film of oil to help prevent rust and sticking. For an extended shutdown, the manual recommends a heavier coat of grease on the plate. Check the vent for obstructions when cool every six months.
Applications
The manual’s operating and cooking guidance covers open-top burner cooking as well as standard-oven baking, roasting, broiling and reheating. It includes temperature and timing guidance for products such as cakes, breads, pies, cookies, chicken, fish portions, baked potatoes and prepared foods. Actual cooking results depend on the food, load and operating conditions; use the manual’s relevant cooking tables as a starting point.
Vulcan Hart V24 Specifications
- Gas Type
- Natural gas or propane
- Model
- V24
- Gas Types
- Natural gas or propane
- Equipment Type
- Gas restaurant range
- Gas Connection
- 3/4" (19 mm) 14 FPT ANSI schedule #40 standard pipe
- Minimum Front Clearance
- 40" (1016 mm)
- Standard Oven Rack Included
- 1
- Standard Oven Rack Positions
- 2
- Natural Gas Regulator Pressure
- 4" W.C. (.99 kPa)
- Propane Gas Regulator Pressure
- 10.0" W.C. (2.5 kPa)
- Minimum Clearance from Combustible Construction, Rear
- 10" (253 mm)
- Minimum Clearance from Combustible Construction, Sides
- 12" (304 mm)
- Minimum Clearance from Noncombustible Construction, Rear
- 6" (152 mm)
- Minimum Clearance from Noncombustible Construction, Sides
- 0"
Frequently Asked Questions
Is Vulcan a good brand for commercial cooking equipment?+
Who makes Vulcan appliances?+
Can the V24 use natural gas or propane?+
What regulator pressure does the V24 manual specify?+
What gas connection does the manual list?+
What clearances are specified for the V24?+
How many oven rack positions does the V24 standard oven have?+
What should I do if the open-top pilot does not light?+
How should I clean the open-top grates and burners?+
Does the V24 parts catalog list replacement components?+
Need Parts for This Model?
Get a free quote for parts, service, or maintenance for the Vulcan Hart V24. We respond within 24 hours.
View all Vulcan Hart equipment →
Parts for the Vulcan Hart V24
Browse genuine OEM components, gaskets, heating elements, thermostats, and replacement hardware guaranteed to fit this equipment.
In Stock 360°Vulcan Hart 00-010901-00050 Orifice - Spud (50 Drill) (PRO/BUT) (4500 to 7499 Ft.)
In Stock 360°Vulcan Hart SD-032-07 Screw, Flanged Hex Head, 10-24 x 1/2"
Available to OrderVulcan Hart 00-499586-00001 Drip Deflector, V-Series Range
In Stock 360°Vulcan Hart 00-010901-00037 Spud Orifice, Natural Gas, 37 Drill, 8500-10500ft
In Stock 360°Vulcan Hart FP-085-42 Fitting, 7/16" Tube to 3/8"MPT
In Stock 360°Vulcan Hart 00-412787-00001 Pilot, Oven, Natural Gas
In Stock 360°Vulcan Hart 00-959573-00001 Pilot Safety Valve
Available to OrderVulcan Hart 00-957911-00002 24 DOOR HANDLE
Available to OrderHobart 00-499980-000G3 TOP FRONT ASSEMBLY,VULCAN 60
Available to OrderHobart FP-035-38 PIPE,1/4 X .875
In Stock 360°Vulcan Hart 00-404193-00001 Pilot Adjusting Valve
In StockVulcan Hart 00-417244-000G1 Shelf Weldment, Stainless Steel, 36L
Available to OrderVulcan Hart 00-958796-00001 Holder, Trough
In Stock 360°Vulcan Hart 00-956840-000G1 Grease Trough Assembly, Griddle
Available to OrderVulcan Hart 00-956837-00002 BROILER MANIFOLD COVER
Available to OrderHobart 00-499591-00002 SIDE BODY,RH,SS
Available to OrderVulcan Hart 00-499993-000G3 TOP, FRONT BOILER ASSEMBLY VULCAN
In StockVulcan Hart 00-418051-00042 Burner Orifice, #42, Natural, 4000-5999 & 6000-7999 FT Elevation
In StockVulcan Hart 00-499674-000G1 Pilot Tube Assembly, Front Open Top
In Stock 360°Vulcan Hart 00-418051-00059 Orifice Hood, Griddle, Liquid Propane Gas, 8000-10000
In Stock 360°Vulcan Hart 00-719951-00052 Burner Orifice, #52 Propane
In Stock 360°Vulcan Hart 00-010901-00053 Orifice Spud, Propane Gas, #53
In Stock 360°Vulcan Hart 00-957910-000G3 Door Assembly, I, V24, V24
Available to Order