The Hobart CL64-ADV is a two-tank conveyor dishwasher with Automatic Soil Removal. Its CL-ADV configuration includes factory-installed drain water tempering; confirm site utilities and configuration requirements before ordering.
- Voltage
- 208/240/480/600V
- Phase
- 3
- Amps
- Varies by voltage and electrical connection26.9–175.0 rated amps
- Wattage
- 25 kW tank heat30 kW built-in booster
Hobart CL64-ADV
22 compatible parts available
Genuine OEM Parts
Sourced from the manufacturer
Canadian Owned
Based in British Columbia
Canada-Wide Shipping
Every province and territory
24hr Quote Response
Answered by a real technician
Manuals & Documents
About the Hobart CL64-ADV
Overview
The Hobart CL64-ADV is a CL-Series conveyor dishwasher. The available product listing identifies this model as a two-tank machine with Automatic Soil Removal (ASR). The CL-Series manual covers the CL-ADV configuration and its installation, operation and troubleshooting. The documentation provided here does not state a rack-per-hour rating, overall dimensions, shipping weight or a complete electrical specification for the CL64-ADV, so those details should be confirmed for the exact machine configuration.
CL-ADV models have a factory-installed Drain Water Tempering (DWT) kit. Unlike CL-BAS models described in the manual, CL-ADV models require both hot- and cold-water connections. If the machine is equipped with gas tank heat, the manual lists gas requirements for the CL64 model; those requirements are included below as conditional configuration information.
Key Features
- Conveyor operation: Dishes travel through the dishwasher on a conveyor.
- Two-tank configuration: The available listing identifies the CL64-ADV as a two-tank model.
- Automatic Soil Removal: ASR is identified as a feature of the CL64-ADV.
- Drain water tempering: The CL-Series manual states that DWT is factory installed on CL-ADV models.
- Service diagnostics: The manual provides CL-Series error messages and troubleshooting guidance, including instructions to contact Hobart Service for specified faults.
Specifications
- Model: Hobart CL64-ADV.
- Product type: CL-Series conveyor dishwasher.
- Tanks: Two, as stated in the available CL64-ADV listing.
- Soil removal: Automatic Soil Removal (ASR).
- Drain water tempering: Factory installed on CL-ADV models.
- Water connections: Hot and cold water supplies are required for CL-ADV models.
- Incoming water temperature with the listed built-in booster: For CL-ADV models in the 64/86 size with a 24 kW built-in booster, the manual lists cold water at 55–80 °F and hot water at a minimum of 110 °F.
- Incoming water pressure: The manual's fill-error troubleshooting instructions specify verifying water pressure of 20–65 psi.
- Incoming water line: The CL-Series manual specifies a minimum 1/2-inch inside diameter for the incoming water line.
- Drain connection: 2-inch NPT pipe; the common tank drain can be connected at either end, with a plug provided for the opposite end.
- Grease trap, if required by code: Minimum flow capacity of 38 gallons per minute.
- Conditional gas heat information for CL64: The manual lists natural or propane gas, 156,000 BTU/hr, and a 3/4-inch NPT connection. Flowing gas pressure is listed as 3.5–7 inches W.C. for natural gas and 9–11 inches W.C. for propane; listed manifold pressures are 3.2 inches W.C. for natural gas and 8.2 inches W.C. for propane. Static incoming line pressure must not exceed 14.0 inches W.C. for either gas. These figures apply only when the machine is equipped with gas tank heat.
Installation & Requirements
Water and drain
CL-ADV models require separate hot- and cold-water supplies. For the CL-ADV 64/86 configuration with a 24 kW built-in booster, the manual specifies cold water at 55–80 °F and hot water at a minimum of 110 °F. It specifies an incoming water line with a minimum 1/2-inch inside diameter. If flowing water pressure exceeds 50 psig, the manual says a pressure regulator with a relief bypass must be used; it warns that an improper regulator may damage the unit. The fill troubleshooting section also directs operators to verify water pressure of 20–65 psi when investigating a tank-fill error.
The common tank drain needs one connection to the floor drain and may be connected at either end of the drain body. Use 2-inch NPT pipe through a trap to the sewer. If a grease trap is required by code, the manual specifies a minimum flow capacity of 38 gallons per minute. On CL-ADV and CL-DWR models, factory drain plumbing may need to be relocated to the opposite side of the drain body to suit the connection. The manual states that the drain water tempering kit is factory installed on CL-ADV models.
Gas heat, when equipped
The available documentation does not provide a complete electrical connection schedule for the CL64-ADV. Confirm the exact machine heat and electrical configuration rather than applying figures from a different CL64 version.
Operation
Before operation, the manual instructs users to make sure the dishwasher is clean and all parts are in place. Tank standpipes, strainer pans, scrap baskets and wash arms are among the components it describes installing. Where a scrapper is fitted, the standpipe with strainer goes in the first tank where the rack enters; the manual specifies a standpipe without a strainer in the second or third tank. Install wash arms with their sliders closed, push each arm onto its connector pipe and position the opposite end in its guide.
The manual's no-operation checks include closed inspection doors, a clear conveyor and an available power supply. If the auto-timer has timed out, it directs the operator to press START or insert a rack. If the machine is in Energy Saver Mode, press WASH on the HMI to resume. A tripped table limit switch can also prevent operation when that switch is used.
Cleaning & Maintenance
The provided manual excerpts do not give a complete daily cleaning schedule or maintenance interval. They do identify components to inspect when wash performance is poor: tank water level and drainage, drain O-rings, wash-arm sliders and nozzles, manifold O-rings, and the pump intake. The manual also says to install the standpipes, strainers, scrap basket and wash arms in their proper positions before operation.
For a suspected pump obstruction, the manual directs the operator to disconnect electrical power and follow lockout/tagout procedures. It warns that multiple circuits may be present and says to verify that all circuits are disconnected. Drain the tank or tanks and check for an obstruction at the pump intake. For service work beyond the listed checks, follow the machine's complete manual and contact Hobart Service where directed.
Troubleshooting
Machine will not operate
- Check for a blown fuse or tripped circuit breaker at the power supply.
- Confirm inspection doors are closed.
- Check whether the conveyor is jammed.
- If the auto-timer has timed out, press START or insert a rack.
- If fitted, check whether the table limit switch has tripped.
- If the machine is in Energy Saver Mode, press WASH on the HMI to resume.
Dishes are not clean
The manual lists insufficient wash water, a drain obstruction that leaves the drain open, and a worn or torn drain O-ring as possible causes. It also lists wash-arm sliders left open, blocked wash-arm nozzles, a worn or torn manifold O-ring, pump obstructions that reduce water pressure, and incorrect water temperature. For temperature checks, the manual points to the electric heat circuit breaker, main steam valve or gas supply valve, as applicable to the machine configuration.
Selected error codes shown in the manual
- 016 and 017: Wash-tank pressure sensor faults. The manual describes a short or open circuit, or a booster water level outside its specified limits, and directs the operator to contact Hobart Service.
- 018: Wash-tank water level too high. Check for drain obstructions and drain the machine; contact Hobart Service if the issue persists or the machine cannot be drained.
- 020 and 023: Tank-fill time exceeded or tank water level did not increase in the set time. Confirm the drain is closed, the incoming water is on and the fill hose is not kinked; verify water pressure is 20–65 psi. Drain and try filling again where directed. Contact Hobart Service if the error persists.
- 029: Wash interrupted because a door was opened during operation; the displayed instruction is to close the doors.
- 083 and 084: Final-rinse temperature too low. Press ENTER to clear the error. For 084, the wash cycle stops and the machine turns off; contact Hobart Service if the error persists.
- 085 and 086: Wash-tank or booster overtemperature trip. Contact Hobart Service.
- 088 and 089: Wash-tank or booster contactor error. The manual says to turn off the machine circuit breaker or breakers, not to drain the machine, and to contact service.
- 094 and 095: Power-rinse tank pressure sensor faults, including a sensor short or open circuit or a tank level outside its specified limits. Contact Hobart Service.
- 100 and 101: Power-rinse temperature sensor faults. Contact Hobart Service.
- 102 and 103: Drain Water Tempering temperature sensor faults. If the DWT assembly is not installed, the manual says to disable DWT in the manager menu; otherwise, contact service.
- 234: External conveyor not ready. Ensure it is powered on, ready and free of errors; contact Hobart Service if the error persists.
Applications
The CL64-ADV's conveyor format and two-tank, automatic soil removal configuration suit commercial dishrooms processing racks of dishes through a continuous wash operation. Its hot- and cold-water requirements, drain arrangement and—if gas heated—gas supply should be checked against the facility's available utilities and the exact machine configuration before purchase.
Hobart CL64-ADV Specifications
- Weight
- 920 lbs
- Voltage
- 208/240/480/600V
- Phase
- 3
- Amps
- Varies by voltage and electrical connection; 26.9–175.0 rated amps
- Wattage
- 25 kW tank heat; 30 kW built-in booster
- Model
- CL64-ADV
- Tank heat
- 25 kW electric
- Wash motor
- 2 HP
- Drive motor
- 1/6 HP
- Rinse motor
- 2 HP
- Product type
- High-temperature rack conveyor dishwashing machine
- Rack capacity
- 342 racks per hour (NSF rated)
- Conveyor speed
- 9.5 feet per minute
- Peak drain flow
- 38 U.S. gallons per minute
- Shipping weight
- 920 lbs. approximate
- Vent connection
- Optional vent hoods; 4" x 16" vent stack with damper
- Drain connection
- 2" FPT; drain may be connected to either side of valve, plug opposite side
- Crated dimensions
- 74"L x 38"W x 78"H
- Standard features
- Automatic soil removal (ASR); Opti-Rinse system; rapid-return conveyor drive; large double door opening; insulated hinged doors with interlock switches; top-mounted microprocessor control; programmable energy saver mode; dirty water indicator; manager-activated low-temperature alert; configurable pot-and-pan dwell mode; configurable delime notification; service diagnostics; self-aligning wash manifolds; stainless steel anti-clogging wash arms; removable pump intake screen; stainless steel self-draining pump and impeller; sloping scrap screen and deep scrap basket; stainless steel perimeter and bottom panels; door-actuated drain closure; convertible hot-water or low-temperature final rinse; vent fan control; booster heater control; ENERGY STAR certified
- Water consumption
- 132 U.S. gallons per hour maximum use at 20 PSI
- Wash tank capacity
- 23 U.S. gallons
- Water use per rack
- 0.39 U.S. gallons
- Operation direction
- Left-to-right or right-to-left
- Rinse tank capacity
- 22 U.S. gallons
- Hot water connection
- 1/2" FPT
- Optional accessories
- Standard, short, and extended stainless steel vent hoods; direct-drive unloader adds 38" length; SL23 side loader adds 23" length; SL30 side loader adds 30" length; blower-dryer adds 33 1/4" length; flanged feet kit; table limit switch with 10' wire; pressure regulator valve for external booster; water shock absorber kit; factory-mounted circuit breakers; field-installed single-point kits for 208/60/3 and 240/60/3 with internal booster
- Cold water connection
- 1/2" FPT
- Drain water tempering
- Factory installed on CL-DWR and CL-ADV models
- Higher chamber option
- 24" opening
- Ventilation, load end
- 200 CFM minimum
- Cold water temperature
- 80°F maximum
- Built-in booster heater
- 30 kW for 70°F rise
- Ventilation, unload end
- 400 CFM minimum
- Water supply for CL-ADV
- Hot and cold water supplies
- Heat dissipation, latent
- 52,300 BTU/hr.
- Internal GFCI protection
- Not provided
- Electrical service options
- 208/60/3, 240/60/3, 480/60/3, 600/60/3
- Heat dissipation, sensible
- 22,400 BTU/hr.
- 208/60/3 dual-point booster
- 83.9 rated amps; 90 minimum supply circuit ampacity / maximum protective device
- 240/60/3 dual-point booster
- 80.2 rated amps; 90 minimum supply circuit ampacity / maximum protective device
- 480/60/3 dual-point booster
- 40.1 rated amps; 50 minimum supply circuit ampacity / maximum protective device
- 600/60/3 dual-point booster
- 26.9 rated amps; 40 minimum supply circuit ampacity / maximum protective device
- Drain water energy recovery
- DWER
- Automatic soil removal motor
- 1/2 HP
- Water hardness recommendation
- 3 grains or less
- Building flowing water pressure
- 20 PSI (+/- 5 PSI)
- Standard chamber opening height
- 19.5"
- 208/60/3 single-point connection
- 175.0 rated amps; 200 minimum supply circuit ampacity / maximum protective device; field-installed SGLPT-KIT3-CLE required
- 240/60/3 single-point connection
- 167.0 rated amps; 200 minimum supply circuit ampacity / maximum protective device; field-installed SGLPT-KIT3-CLE required
- 480/60/3 single-point connection
- 85.0 rated amps; 100 minimum supply circuit ampacity / maximum protective device; factory-installed
- 600/60/3 single-point connection
- 59.1 rated amps; 80 minimum supply circuit ampacity / maximum protective device; factory-installed
- Minimum incoming water temperature
- 110°F for 30kW internal booster
- Electrical connection configuration
- Dual-point standard on 208/60/3 and 240/60/3; single-point standard on 480/60/3 and 600/60/3
- Electrical configuration in spec sheet
- CL64 eN-ADV electric
- 208/60/3 dual-point tank heat, motors and controls
- 90.6 rated amps; 125 minimum supply circuit ampacity / maximum protective device
- 240/60/3 dual-point tank heat, motors and controls
- 86.6 rated amps; 125 minimum supply circuit ampacity / maximum protective device
- 480/60/3 dual-point tank heat, motors and controls
- 44.9 rated amps; 60 minimum supply circuit ampacity / maximum protective device
- 600/60/3 dual-point tank heat, motors and controls
- 32.2 rated amps; 45 minimum supply circuit ampacity / maximum protective device
- Incoming water temperature for CL-ADV with 24kW booster
- Cold water 55°F minimum, 80°F maximum; hot water 110°F minimum
Frequently Asked Questions
What is the Hobart CL64-ADV?+
How many racks per hour can the CL64-ADV wash?+
What water connections does the CL64-ADV require?+
What drain connection does the CL64-ADV use?+
Does the CL64-ADV include drain water tempering?+
What are common CL-Series dishwasher problems?+
Which error codes might an operator encounter?+
What is the average lifespan of a Hobart commercial dishwasher?+
Are Hobart dishwashers good?+
What should I check if the machine will not start?+
Need Parts for This Model?
Get a free quote for parts, service, or maintenance for the Hobart CL64-ADV. We respond within 24 hours.
View all Hobart equipment →
Parts for the Hobart CL64-ADV
Browse genuine OEM components, gaskets, heating elements, thermostats, and replacement hardware guaranteed to fit this equipment.
In Stock 360°Hobart 00-087714-042-3 Relay, 240V Coil, DPST, 20A
In Stock 360°Hobart 00-941233-00005 Shaft Seal, Pump, AM15VLF
In Stock 360°Hobart 00-118317 Steam Trap, 3/4", 21-50 PSI
In Stock 360°Hobart 00-328994 Probe Assembly, Rinse
In Stock 360°Hobart 00-941233-00010 O-Ring, Rubber, Pump Motor, AM15
In Stock 360°Hobart 00-563609 SENSOR
In StockHobart 00-067500-00014 O-Ring, Upper Wash Arm
In Stock 360°Hobart 00-936333-00001 Element with O-Ring, 200 Volt, 10KW
In Stock 360°Hobart 00-087714-042-5 Relay, DPST, 24VDC, 30A
In Stock 360°Hobart 00-748572 Electrode Assembly
In Stock 360°Hobart 00-814624 Switch Assembly, Interlock
In Stock 360°Hobart 00-975431 Extension Board Assembly, EC, A7
Available to Order 360°Hobart 00-936333-00004 Element, 440V, 10KW
In Stock 360°Hobart 00-562597-00001 Contactor, 120 Volt Coil, 4 Pole
Available to OrderHobart 00-067500-00034 O-Ring, Element Seal
In Stock 360°Hobart 00-892004-00002 Solenoid Valve, Steam, 120V, 60HZ, 3/4"
In Stock 360°Hobart 00-328426-00004 Gas Valve with Regulator, 25 Volt, 60HZ, 30 Amp
Available to Order 360°Hobart 00-975433 Extension Board Assembly, EC, A6
Available to Order 360°Hobart 00-974568-00002 Heating Element Kit, 220 Volt, 15KW
In Stock 360°Hobart 00-949039 Probe Assembly, PW10eR, PW20eR
In StockHobart 00-067500-00120 O-Ring, Overflow Tube
In Stock 360°